MX304

Specifications

System capacity

4.8 Tbps

DPCs and/or MPCs per chassis

N/A

LMICs and REs per chassis

1 RE and 3 LMICs or 2 REs (RE redundancy) and 2 LMICs

Chassis per rack

22

Dimensions (W x H x D)

17.3 x 3.5 x 24 in (8.89 x 44 x 61 cm)

Maximum weight

66.1 lb (30 kg) with a 2 Routing Engine configuration

Mounting

2/4-post rack mounting

Power options

100-240 VAC / 50-60 Hz or -48 VDC at 60A or HVAC/HVDC (180VAC – 305VAC / 190VDC – 410VDC)

Operating temperature

32° to 115° F (0° to 46° C) at sea level

Humidity

(Operating) 5 to 90 percent noncondensing

Altitude

Up to 6000 feet